MATERIAL -------- 1 power suupply (5V @ 2 A) 1 VME crate 6U with: 1 Control-X board 1 Patgen board 1 ROS-8 board 1 cable ROBUS with 3 ODU connectors External Termination of the ROBUS Power cable 4 signal cables 3 twisted pair cables 1 pair to Ethernet RJ45 cable Twisted pairs: One of them goes from Control-X PLS0 output to Patgen lower pins input. Positive always on the right. One of them goes from any of the Control-X CLKn outputs to the clock connector on the ROB J11 (polarity important depending on ROBUS lenght: cpujtag interference) One of them goes from any of the Control-X CLKn outputs to the clock connector on the ROS J22 upper (polarity not important) Set in the ROB one addres with switch S1. Leave swithc 4 UP (not like in the Minicrate). Better if you put all switch to 0 OPEN C:\CMS_cris\TEST_prod_ROB128_v2\TEST_prod_ROB128 and execute ROB TEST.llb Select "t_ROB TEST.vi" Run it. you will need to adjust the timing depending on the signal cable´s length.